Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Int J Equity Health ; 20(1): 197, 2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-34461895

RESUMO

BACKGROUND: Most estimates of visual impairment and blindness worldwide do not include data from specific minority groups as indigenous populations. We aimed to evaluate frequencies and causes of visual impairment and blindness in a large population sample from the Xingu Indigenous Park. METHODS: Cross-sectional study performed at Xingu Indigenous Park, Brazil, from 2016 to 2017. Residents from 16 selected villages were invited to participate and underwent a detailed ocular examination, including uncorrected (UVA) and best-corrected visual acuity (BCVA). The main cause of UVA < 20/32 per eye was determined. RESULTS: A total of 2,099 individuals were evaluated. Overall, the frequency of visual impairment and blindness was 10.00% (95% CI: 8.72-11.29%) when considering UVA, decreasing to 7.15% (95% CI: 6.04-8.25%) when considering BCVA. For each increasing year on age, the risk  of being in the visually impaired or blind category increased by 9% (p < 0.001). Cataracts (39.1%) and uncorrected refractive errors (29.1%) were the most frequent causes of visual impairment and blindness in this population. The main causes among those aged 45 years and more were cataracts (54.5%) while refractive errors were the main cause in adults aged 18 to 45 years (50.0%) and children up to 18 years old (37.1%). CONCLUSIONS: A higher frequency of visual impairment and blindness was observed in the indigenous population when compared to worldwide estimates with most of the causes being preventable and/or treatable. Blindness prevention programs should focus on accessibility to eye exam, cataract surgeries and eyeglass distribution.


Assuntos
Cegueira , Baixa Visão , Adolescente , Adulto , Cegueira/epidemiologia , Cegueira/etiologia , Brasil/epidemiologia , Criança , Pré-Escolar , Estudos Transversais , Disparidades nos Níveis de Saúde , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Grupos Populacionais/estatística & dados numéricos , Prevalência , Baixa Visão/epidemiologia , Baixa Visão/etiologia , Adulto Jovem
2.
Clin Ophthalmol ; 13: 953-958, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31289436

RESUMO

PURPOSE: The aim of this study was to evaluate the influence of four different types of speculums on aberrometry reading (OPD SCAN III [OPD]) and on intraoperative aberrometry reading (optiwave response analyzer, ORA). PATIENTS AND METHODS: This prospective, controlled, comparative study of consecutive cases included the evaluation of five eyes of five patients with monofocal intraocular lens (IOL) implantation. Seventeen measures were performed on each patient: for each speculum, there were two measurements on the OPD and another two on ORA with four different types of blepharostats. A control measure was performed on the without blepharostat in the dominant eye of each patient, therefore totalizing 85 measurements. The measures with the blepharostats were as follows: without pressure (WF) or passive measure and after pressure (AF) or active measure to close the eye. The speculum used in all patients was as follows: open-edged wire (Barraquer); threaded with open blade (Lieberman), with 21 mm aperture; wired with solid blade (Barraquer); and threaded with solid blade (Lieberman) with 21 mm opening. An evaluation of the objective refractive data from the OPD and ORA and the corneal astigmatism from the OPD was performed. RESULTS: Spherical equivalent (SE) of the OPD with the use of blepharostat compared to the OPD without speculum presented only 37.5% of results without statistical significance. Regarding the SE of ORA with speculum usage, compared to the OPD without blepharostat, only 12.5% were not significant. Regarding the accuracy of the ORA refractive axis with the use of blepharostats, all results presented statistical significance. CONCLUSION: Thus, in the present study, we reached the conclusion between the studied blepharostats that the most suitable for use in the aphakic and pseudophakic capture of the ORA is the open blade threaded blepharostat (Lieberman).

3.
Clin Ophthalmol ; 13: 49-52, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30643379

RESUMO

PURPOSE: To compare intraoperative parameters between venturi and peristaltic pump in WhiteStar Signature® phacoemulsification machine using the bevel-down technique. SETTING: Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil. DESIGN: Prospective, comparative, patient-masked study. METHODS: Three hundred eyes were randomly assigned to have a phacoemulsification procedure with WhiteStar Signature® using either peristaltic (n=150 eyes) or venturi (n=150 eyes) pumps by a single surgeon (WTH). Elliptical ultrasound setting and prefracture (prechop or preslice) techniques were used in all cases. Cataract nucleus density was graded using lens opacities classification system III and Pentacam Nucleus Staging classification. Clinical measurements included preoperative- and postoperative- corrected visual acuity, preoperative and 2-month postoperative endothelial cell counts, and preoperative and 1-day postoperative central corneal thickness. Intraoperative measurements at the end of the case were phaco time, fluid used, total case time, and Efx energy. RESULTS: There were no statistically significant differences between groups regarding age, cataract density, and phaco time (P>0.05). Intraoperatively, we observed significantly less ultrasound energy (P=0.011), case time (P=0.0001), and balanced saline solution (P=0.001) usage in the venturi group. Clinically, both fluidic settings can provide similar clinical outcomes and visual recovery, regarding corrected distance visual acuity, endothelial cell count, and central corneal thickness. CONCLUSION: Our data show that to minimize fluid use, case time, and energy with the prefracture technique, the venturi pump was the most efficient system and was statistically superior to peristaltic pump.

4.
Arq Bras Oftalmol ; 79(3): 171-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27463628

RESUMO

PURPOSE: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. METHODS: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. RESULTS: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. CONCLUSION: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.


Assuntos
Implante de Lente Intraocular/métodos , Lentes Intraoculares , Acuidade Visual/fisiologia , Aberrometria , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Período Pré-Operatório , Desenho de Prótese , Valores de Referência , Refração Ocular , Resultado do Tratamento
5.
Arq. bras. oftalmol ; 79(3): 171-176, tab, graf
Artigo em Inglês | LILACS | ID: lil-787325

RESUMO

ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.


RESUMO Objetivo: Comparar o desempenho óptico e resultado visual entre duas lentes multifocais difrativas: AMO Tecnis® ZMB00 e AcrySof® ReSTOR® SN6AD1. Métodos: O estudo prospectivo, comparativo não randomizado incluiu avaliação de 74 olhos em 37 pacientes com indicação de facectomia e candidatos a implante de lente multifocal. Critérios de exclusão foram: presença de outras doenças oculares; cirurgia ocular prévia; alta miopia axial; astigmatismo cornenano maior que 1,00 D cilíndrica; complicações intraoperatórias ou pós-operatórias. A avaliação oftalmológica contou com medida da acuidade visual para longe corrigida (CDVA) e não corrigida (UDVA), intermediária (DCIVA) e curta distância (DCNVA) com melhor correção óptica para longe; teste de sensibilidade ao contraste; análise de frente de onda e curva visual de Defocus. Resultados: A UDVA foi de 0,09 logMAR para o grupo SN6AD1 e 0,08 logMAR para o grupo ZMB00; com correção foi de 0,04 logMAR para SN6AD1 e 0,02 para o grupo ZMB00 (p>0,05). O grupo SN6AD1 obteve valor de 0,04 logMAR e o grupo ZMB00 de 0,09 logMAR para DCNVA (p<0,05) e DCIVA de 0,17 logMAR para SN6AD1 e 0,54 logMAR para ZMB00 (p=0,000). Houve melhora do equivalente esférico e da UDVA em ambos os grupos (p<0,05). Em condições fotópicas, o grupo SN6AD1 teve melhor sensibilidade ao contraste em baixas frequências sem ofuscamento (p<0,05), contudo grupo ZMB00 obteve melhor sensibilidade em altas frequências (p<0,05) com ofuscamento. As lentes SN6AD1 e ZMB00 obtiveram comportamento semelhantes para visão intermediária na curva de Defocus, porém, o grupo ZMB00 mostrou menor distância de leitura que o grupo SN6AD1. Não houve diferença com significância estatística relacionada à aberrometria na comparação dos dois grupos. Conclusão: As duas lentes promoveram melhor qualidade de visão para longe e perto e comportamento semelhante para visão intermediária. O grupo ZMB00 exibiu melhores resultados para sensibilidade ao contraste em condições fotópicas em alta frequência espacial e SN6AD1 em baixa frequência espacial.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Acuidade Visual/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Período Pós-Operatório , Desenho de Prótese , Valores de Referência , Refração Ocular , Análise de Variância , Resultado do Tratamento , Aberrometria , Período Pré-Operatório
6.
Arq Bras Oftalmol ; 78(1): 19-22, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25714532

RESUMO

PURPOSE: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. METHODS: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). RESULTS: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). CONCLUSION: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip.


Assuntos
Córnea/cirurgia , Facoemulsificação/instrumentação , Idoso , Idoso de 80 Anos ou mais , Contagem de Células , Endotélio Corneano/citologia , Desenho de Equipamento , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Facoemulsificação/métodos , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Acuidade Visual/fisiologia
7.
Arq. bras. oftalmol ; 78(1): 19-22, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741162

RESUMO

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Córnea/cirurgia , Facoemulsificação/instrumentação , Contagem de Células , Desenho de Equipamento , Endotélio Corneano/citologia , Período Intraoperatório , Duração da Cirurgia , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Facoemulsificação/métodos , Método Simples-Cego , Resultado do Tratamento , Acuidade Visual/fisiologia
8.
Br J Ophthalmol ; 99(5): 654-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25385061

RESUMO

PURPOSE: To compare the anti-inflammatory efficacy of ketorolac of tromethamine 0.4% and nepafenac 0.1% eye drops for prophylaxis of cystoid macular oedema (CME) after small-incision cataract extraction. METHODS: Patients were assigned randomly to three groups. Group 1 patients received a topical artificial tear substitute (placebo); group 2 received ketorolac tromethamine 0.4% (Acular LS, Allergan) and group 3 received nepafenac 0.1% (Nevanac, Alcon). The incidence and severity of CME were evaluated by retinal foveal thickness on optical coherence tomography (OCT) after 1, 4 and 12 weeks. RESULTS: One hundred and twenty-six eyes of 126 patients were included in this study. The between-group differences in visual outcomes, central corneal thickness and endothelial cell density were not statistically significant. In all retinal thickness measurements, an increase was detected starting from the postoperative first week until 12 weeks. There was no statistically significant difference between the three groups in any measurement performed by spectral-domain OCT. CONCLUSIONS: Used prophylactically after uneventful cataract surgery, non-steroidal anti-inflammatory drugs were not efficacious in preventing macular oedema compared with placebo. TRIAL REGISTRATION NUMBER: ClinicalTrials: NCT02084576.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Benzenoacetamidas/uso terapêutico , Cetorolaco/uso terapêutico , Edema Macular/prevenção & controle , Facoemulsificação , Fenilacetatos/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/administração & dosagem , Benzenoacetamidas/administração & dosagem , Feminino , Humanos , Cetorolaco/administração & dosagem , Implante de Lente Intraocular , Edema Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Fenilacetatos/administração & dosagem , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos , Refração Ocular/fisiologia , Retina/patologia , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
9.
Rev. bras. oftalmol ; 73(6): 329-334, Nov-Dec/2014. tab, graf
Artigo em Português | LILACS | ID: lil-741907

RESUMO

Objetivo: Medir e comparar o tamanho e forma de capsulotomias realizadas com laser de femtossegundo com os de capsulorrexes curvilíneas contínuas (CCC) realizadas com auxilio guiado por imagem digital e avaliar o resultado refracional. Métodos: Durante cirurgia de catarata, 40 olhos de 40 pacientes tiveram a capsulotomia realizada com auxílio do laser de femtossegundo e seus resultados foram comparados com os de 40 olhos de 40 outros pacientes que tiveram a capsulorrexe guiada por sistema de imagem digital. Os parâmetros de circularidade, forma e overlap foram medidos usando o Adobe Photoshop (Adobe Systems Inc.) e os resultados refracionais pós-operatórios foram avaliados em ambos os grupos. Resultados: Os diâmetros, tamanho e forma de alta precisão e previsibilidade foram atingidos com laser de femtossegundo e houve diferença estatística entre os grupos. Quando comparado o equivalente esférico entre os grupos, não houve diferença estatística. Conclusão: As capsulotomias realizadas pelo laser de femtossegundo possuem circularidade programada, diâmetro pretendido e valores de desvio padrão médios, indicando resultados reprodutíveis mais elevados. No entanto, CCC realizada por um cirurgião experiente com auxílio guiado de imagem digital, com configurações apropriadas, fornece resultados semelhantes e sugere que diferentes técnicas são igualmente eficazes. .


Purpose: To measure and compare size and shape parameters of femtosecond laser capsulotomy with manually continuous curvilinear digital guided capsulorhexis (CCC) and their refractive outcomes. Methods: Laser capsulotomies in 40 eyes of 40 patients were performed using LenSx femtosecond laser device (Alcon, Forthworth, US) and its results were compared with the CCC digital guided carried out in 40 eyes of 40 patients using the Callisto Eye digital image system (Zeiss, Germany). Capsulorhexis circularity, shape and capsule overlap were measured using Adobe Photoshop (Adobe Systems Inc.) and postoperative refraction outcomes were evaluated in both groups. Results: Highly accurate and predictable capsulotomy diameter, size and shape were achieved with femtosecond laser capsulotomy compared with capsulorhexis and showed statistical difference between groups. Spherical equivalent comparison between groups showed no statistical difference. Conclusions: Femtosecond laser anterior capsulotomy with programed circularity had the intended diameter with average standard deviation values, indicating higher reproducible outcomes. Capsulorhexis performed by an experienced surgeon with auxiliary image guide and appropriate settings provides similar results our results suggest that different techniques are equally effective. .


Assuntos
Humanos , Idoso , Extração de Catarata/métodos , Facoemulsificação/métodos , Capsulorrexe/métodos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Capsulotomia Posterior/métodos , Estudo Comparativo , Microscopia Eletrônica de Varredura , Estudos Prospectivos , Implante de Lente Intraocular , Cápsula Anterior do Cristalino/cirurgia
10.
Arq Bras Oftalmol ; 77(2): 71-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25076467

RESUMO

PURPOSE: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. METHODS: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. RESULTS: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. CONCLUSION: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.


Assuntos
Astigmatismo/cirurgia , Extração de Catarata/métodos , Catarata/complicações , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Idoso , Astigmatismo/complicações , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Feminino , Humanos , Masculino , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
11.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-716265

RESUMO

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Astigmatismo/cirurgia , Extração de Catarata/métodos , Catarata/complicações , Lentes Intraoculares , Implante de Lente Intraocular/métodos , Astigmatismo/complicações , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
12.
J Cataract Refract Surg ; 40(4): 514-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24530022

RESUMO

UNLABELLED: We describe a modification of the original standard radial aspiration technique. The modified technique--hurricane 1-step continuous circular cortical aspiration--has the potential to improve this part of phacoemulsification surgery with benefits in surgical time and possible decreases in fluid, corneal edema, and traction on the zonular fibers through better distribution of tractional forces. The first results were encouraging and without complications. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Córtex do Cristalino/cirurgia , Facoemulsificação , Sucção/métodos , Humanos , Duração da Cirurgia
13.
Rev. bras. oftalmol ; 72(6): 388-395, nov.-dez. 2013. tab
Artigo em Português | LILACS | ID: lil-704741

RESUMO

OBJETIVO: Elaborar e validar o questionário de qualidade de vida na versão do idioma português. MÉTODOS: O questionário "Cataract TyPESpecification" modificado foi desenvolvido especificamente para avaliar a qualidade de vida pós-cirurgia de catarata. O questionário avaliou 10 itens status funcionais por meio de 18 perguntas. Foi aplicado por um único examinador, com o objetivo de graduar a satisfação visual de 0 a 10 (0 muito insatisfeito; 5 neutro; 10 muito satisfeito). Houve estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata da Universidade de São Paulo. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distâncias, sem correção e com a melhor correção óptica e questionário de satisfação. Foi submetido a um questionário de satisfação quanto à acuidade visual e fenômenos fóticos. Todos os exames foram realizados com 6 meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7 ± 6,6 anos no grupo Tecnis, 63,1 ± 4,4 anos no grupo Restor e 63,7 ± 4,2 anos no grupo SN60AT/SN60WF. A acuidade visual para perto não-corrigida e a corrigida para longe foram estatisticamente superiores nos grupos Restor® e Tecnis® comparadas ao grupo SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos quando comparadas a acuidade visual para longe não-corrigida e a melhor corrigida (p=0,56). O questionário de satisfação apresentou maior independência de óculos a favor da Tecnis® (9,3/10) e Restor® (8,7/10), mas com mais queixas de halos (Restor® 18,8%; Tecnis® 21,7%) e glare (Restor® 25%; Tecnis® 26,1%) do que no grupo SN60AT/SN60WF. CONCLUSÃO: A Restor® e Tecnis® apresentaram melhor acuidade visual para perto do que o grupo SN60AT/SN60WF. As lentes Restor® e Tecnis® apresentaram maior satisfação na visão de perto e independência do uso de óculos e fenômenos fóticos do que as lentes monofocais...


PURPOSE: Development and validation of quality of life questionnaire in pseudophakic patients in Portuguese. METHODS: The modified Cataract TyPESpecification questionnaire was specifically developed to assess quality of life after cataract surgery, functional status evaluated with 10 items and contains 18 questions. All questions were applied by a single examiner, with the goal of graduating visual satisfaction from 0 to 10 (0 means very dissatisfied, 5 neutral, 10 very satisfied).This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity and quality of life questionaire. The minimum follow-up was 6 months. RESULTS: The mean age of patients was 60.7± 6.6 years in theTecnis®MF, 63.1 ±4.4 years in-groupRestor®63.7±4.2 years in-group SN60AT/SN60WF. Uncorrected and distance-corrected near visual acuity were statistically higher in theRestor® and Tecnis® groups compared to the SN60AT/SN60WF group (p<0.001). There were no statistical differences between groups comparing uncorrected and best-corrected distance visual acuity (p=0.56). Satisfaction questionnaire showed high glasses independence fortheTecnis®MF (9.3 /10) and Restor® (8.7 /10), but with more unsatisfied of halos (18.8% Restor®, Tecnis®21, 7%) and glare (Restor® 25%;Tecnis®26.1%) than the group SN60AT/SN60WF. CONCLUSION: Cataract patients who received multifocal (Restor®; Tecnis®MF) IOLs at time of surgery obtained better uncorrected and distance corrected near visual acuity and reported better overall vision, less limitation in visual function, less spectacle dependency, and more glare or halo than those who received monofocal (SN60AT; SN60WF) IOLs. Cataract TyPESpecification questionnaire was a strong predictor of change in patient satisfaction caused by cataract surgery.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Extração de Catarata , Implante de Lente Intraocular , Satisfação do Paciente , Qualidade de Vida , Acuidade Visual , Estudos Prospectivos , Inquéritos e Questionários
14.
Rev. bras. oftalmol ; 72(5): 287-293, set.-out. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-690697

RESUMO

OBJETIVO: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. MÉTODOS: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC-FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Todos os exames foram realizados com seis meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7±6,6 anos no grupo Tecnis, 63,1±4,4 anos no grupo Restor e 63,7±4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF). A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56). A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001). A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001). A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001). CONCLUSÃO: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações ópticas e melhor visão intermediária que o grupo Restor.


OBJECTIVE: Comparison of the visual performance between patients with Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60AT and Acrysof® SN60WF intraocular lenses. METHODS: This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity, contrast sensitivity measurement and wavefront analysis. The minimum follow-up was 6 months. RESULTS: The mean age of patients was 60.7±6.6years in the Tecnis®MF, 63.1±4.4 years in-group Restor® 63.7±4.2 years in monofocal group (SN60AT in the fellow eye SN60WF). The Restor and Tecnis groups has uncorrected near and corrected distance visual acuity statistically superior compared to SN60AT/SN60WF group (p<0.001). There was no statistical difference between groups when compared uncorrected and best-corrected distance visual acuity (p=0.56). Contrast sensitivity in photopic conditions was significantly lower in the Restor and Tecnis group (p<0.001). The SN60AT showed higher spherical aberration compared to all other lenses (p<0.001). The Tecnis showed a lower mean values of spherical aberration compared to Restor lenses (p<0.001). CONCLUSION: Restor and the Tecnis had better near visual acuity than the SN60AT/SN60WF group. All intraocular lenses promoted good distance vision. The Tecnis group showed better contrast sensitivity, less aberrations and better intermediate vision than the Restor group.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Catarata , Lentes Intraoculares , Satisfação do Paciente , Pseudofacia , Estudos Prospectivos
15.
Arq. bras. oftalmol ; 75(6): 427-429, nov.-dez. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-675628

RESUMO

A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.


Paciente de 51 anos, sexo feminino, apresentando catarata foi submetida a cirurgia de facoemulsificação com implante de lente intraocular (LIO) multifocal Tecnis ZM900 em ambos os olhos (AO). Durante a implantação da LIO no olho esquerdo, a lente foi inadvertidamente implantada invertida e deixada dessa maneira. Seis meses pós-operatório a surpresa refracional não se mostrou significativa e a acuidade visual corrigida era de 20/20 em AO, sem nenhuma queixa de desconforto visual. Em conclusão, no presente caso, o implante de uma LIO Tecnis multifocal invertida resultou em boa acuidade visual final e sem diferenças significativas na aberrometria em comparação ao olho contralateral, tendo sido possível conduzir o caso de maneira conservadora.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Implante de Lente Intraocular/efeitos adversos , Facoemulsificação , Catarata/complicações , Implante de Lente Intraocular/métodos , Erros Médicos , Acuidade Visual
16.
Rev. bras. oftalmol ; 71(1): 48-52, jan.-fev. 2012. ilus
Artigo em Português | LILACS | ID: lil-618318

RESUMO

O objetivo é descrever uma nova técnica cirúrgica para fixação iriana de lente intraocular durante transplante de córnea em pacientes sem suporte capsular. A técnica de fixação iriana Tied Out Open Sky é uma técnica de fácil execução comparado com as técnicas já descritas, dispensando manobras cirúrgicas complexas, minimizando a manipulação e as complicações pós-operatórias.


To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.


Assuntos
Humanos , Feminino , Adulto , Iris/cirurgia , Técnicas de Sutura/instrumentação , Ceratoplastia Penetrante/métodos , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Afacia , Polipropilenos , Materiais Biocompatíveis , Acuidade Visual , Exotropia , Subluxação do Cristalino , Polietilenotereftalatos , Doenças da Córnea/cirurgia , Cápsula do Cristalino/patologia
17.
Arq Bras Oftalmol ; 75(6): 427-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23715148

RESUMO

A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.


Assuntos
Implante de Lente Intraocular/efeitos adversos , Facoemulsificação , Catarata/complicações , Feminino , Humanos , Implante de Lente Intraocular/métodos , Erros Médicos , Pessoa de Meia-Idade , Acuidade Visual
18.
Rev. bras. oftalmol ; 70(1): 7-10, jan.-fev. 2011. tab
Artigo em Português | LILACS | ID: lil-581586

RESUMO

OBJETIVO: Determinar o efeito de gatifloxacina 0,3 por cento tópica, nas culturas de humor aquoso humano, instilada quatro vezes ao dia por três dias antes de facoemulsificação comparada a uma gota gatifloxacina 0,3 por cento tópica instilada imediatamente antes da cirurgia. MÉTODOS: Trinta e sete pacientes com catarata sem outras afecções oculares foram distribuídos aleatoriamente nos Grupos A e B antes da facoemulsificação. Os pacientes do Grupo A receberam uma gota de gatifloxacina 0,3 por cento imediatamente antes da cirurgia e o Grupo B recebeu gatifloxacina 0,3 por cento quatro vezes ao dia três dias antes do procedimento. Após a facoemulsificação, o humor aquoso foi aspirado e semeado em meios de ágar-sangue, ágar-chocolate, Saboraud e TSB. Foi realizado esfregaço para bacterioscopia. RESULTADOS: O Grupo B apresentou 40 por cento das lâminas bacterioscópicas com cocos gram +. O Grupo B apresentou 17,6 por cento de cocos gram + na bacterioscopia, estes resultados não foram estatisticamente significativos (p=0,098). Cinco casos (25 por cento) do Grupo A apresentaram culturas positivas para Staphylococos epidermidis, resultado significativamente maior do que o Grupo B, que não apresentou nenhuma cultura positiva para bactérias ou fungos. CONCLUSÃO: Neste estudo, a gatifloxacina 0,3 por cento instilada três dias antes da facoemulsificação diminuiu significativamente o número de culturas do humor aquoso positivas quando comparada à instilação imediata de uma gota.


Purpose: To determine the effect on human aqueous humor cultures of topical gatifloxacin 0.3 percent applied four times a day three days before phacoemulsification compared to topical gatifloxaxin 0.3 percent applied and same-day surgery. METHODS: Thirty-seven patients with cataract without other ocular diseases were randomly assigned to Groups A and B before phacoemulsification. Group A received topical gatifloxacin 0.3 percent same-day surgery and Group B received gatifloxacin 0.3 percent four times a day three days before phacoemulsification. After the procedure the aqueous humor was aspirated for cultures on agar-blood, agar-chocolate, saboraud and TSB and smeared for bacterioscopy. RESULTS: Group A presented 40 percent of the bacterioscopies with cocci gram +, Group B presented 17.6 percent of the bacterioscopies with cocci gram +. These results are not statistically significant (p=0,098). Five cases (25 percent) from Group A presented positive cultures for S. epidermidis, which was significantly higher than Group B, which did not present positive cultures for any bacteria or fungus (p=0,027). CONCLUSION: Gatifloxacin 0.3 percent applied three days before phacoemulsification significantly lowered the rate of positive aqueous humor cultures when compared to immediate application of this antibiotic before surgery in this study.


Assuntos
Humanos , Antibacterianos/administração & dosagem , Bactérias/isolamento & purificação , Humor Aquoso/citologia , Facoemulsificação , Estudos de Casos e Controles
19.
Rev. bras. oftalmol ; 69(6): 372-377, nov.-dez. 2010. graf, tab
Artigo em Português | LILACS | ID: lil-624792

RESUMO

OBJETIVO: O objetivo desse estudo é comparar acuidade visual, sensibilidade ao contraste, velocidade de leitura e a qualidade de vida pós-operatória de pacientes pseudofácicos unilaterais ou bilaterais com lentes intraoculares multifocais ReZoom. MÉTODOS: Estudo comparativo, prospectivo, não aleatório incluindo 38 olhos de 24 pacientes, separados em um grupo com implante bilateral (14 pacientes) e outro com implante unilateral (10 pacientes). O exame oftalmológico completo incluiu acuidade visual não corrigida pré-operatória para perto, intermediário e para longe, acuidade visual com melhor correção, topografia corneal, sensibilidade ao contraste, velocidade de leitura e escala de satisfação realizado 60 dias após a cirurgia. A análise estatística foi realizada por meio dos testes de Kruskal-Wallis, Mann-Whitney e Qui-quadrado. RESULTADOS: Os resultados comparando função visual, sensibilidade ao contraste, velocidade de leitura e escala de satisfação foram semelhante entre os grupos. CONCLUSÃO: Não houve diferença estatística entre os resultados comparando função visual, sensibilidade ao contraste, velocidade de leitura e escala de satisfação entre os grupos.


PURPOSE: The aim of this study is to compare visual acuity, contrast sensitivity, reading speed and quality of life of postoperative pseudophakic patients with unilateral or bilateral ReZoom multifocal intraocular lenses. METHODS: Comparative, prospective, not randomized study including 38 eyes of 24 patients were divided into a group with bilateral implantation (14 patients) and another with unilateral implantation (10 patients). The ophthalmological examination included visual acuity preoperative close, intermediate and far away, best corrected visual acuity, corneal topography, contrast sensitivity, reading speed and level of satisfaction achieved 60 days after surgery. Statistical analysis was performed using the Kruskal-Wallis, Mann-Whitney and Chi-square test. RESULTS: The results comparing visual function, contrast sensitivity, reading speed and scale of satisfaction were similar between groups. CONCLUSION: There was no statistical difference between the results comparing visual function, contrast sensitivity, reading speed and level of satisfaction between the groups.

20.
Arq Bras Oftalmol ; 72(4): 526-32, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19820794

RESUMO

PURPOSE: To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS: This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS: Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75% achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75% of the eyes achieved more than Jaeger 6. At least 87.5% of the multifocal group and 6.3% of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5) or better. And 90.0% of the eyes in the multifocal group and 37.5% in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6) or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379). The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units) with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014) and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units) under mesopic conditions (p=0.044). CONCLUSION: The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.


Assuntos
Sensibilidades de Contraste , Implante de Lente Intraocular , Facoemulsificação/métodos , Acuidade Visual , Idoso , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...